在網絡基礎設施中的可靠性
白皮書, 中國
2014年2月//采用戈爾?防水透氣產品的29件塔頂放大器和合路器經受了長達11年的現(xiàn)場檢查和完整性測試。所有裝置均超過了建議的透氣量,且90%的裝置通過了IPX7浸沒測試,這體現(xiàn)了防水透氣產品的卓越可靠性。
Internal pressure fluctuations in telecommunications equipment put significant stress on the housing seals, which over time can result in compromising the seals and the equipment’s reliability. These fluctuations are most frequently caused by sudden weather and temperature changes in the outdoor environments in which the equipment must operate. Once the seals fail, contaminants such as rain, dust, and dirt can enter the housing and cause premature failure of the electronics.
GORE? Protective Vents are engineered to eliminate stress and damage on seals by allowing air to flow freely in and out of electronic housings. Based on their research on the impact of pressure differentials on sealed enclosures, W. L. Gore & Associates recommends maintaining internal pressure at or below 35 millibars (mbar). Gore’s engineering team bases its vent recommendations for each application on such variables as volume of enclosure, amount of internal free space, level of water and contaminant protection required, enclosure materials of construction, and environmental conditions in which the device will be used. By evaluating these variables, Gore is able to specify the best venting solution to reduce the impact of pressure differentials and increase the lifetime performance of telecommunication equipment.
To evaluate the performance of GORE Protective Vents after extended exposure to real-world conditions, Gore decided to test vents that had been in telecommunication equipment operating throughout the world for several years. Each vent was evaluated for water protection integrity and airflow.
僅用于工業(yè)用途
不可用于食品、藥品、化妝品或醫(yī)療設備等的制造、加工或包裝作業(yè)